Seanav Marine

Inflatable Life Raft Annual Servicing & Hydrostatic Release (HRU) Renewal India

IMO Res. A.761(18) Approved Accredited Partner Stations 24-Hour Exchange Rafts Available
Official Statutory Service Scope

Seanav Marine coordinates statutory annual servicing, pressure testing, and hydrostatic release unit (HRU) renewals for marine inflatable life rafts across all Indian ports through accredited partner service stations. We test VIKING, Survitec, Lalizas, and Fujikura rafts with Class certificates, ensuring seamless turnaround during vessel cargo operations.

Supported OEM Equipment & Multi-Make Coverage

Our marine electronics engineers are factory-trained with proprietary OEM diagnostic interfaces, software keys, and genuine spare parts for leading bridge manufacturers:

Furuno VR-3000 / VR-7000 / FAR-2xx8 / FMD-3x00 JRC JCY-1800 / JCY-1900 / JMR-9200 / JAN-9201 Sperry Marine VisionMaster FT / Navigat 100/200 Tokyo Keiki TG-8000 / BR-3200 / PR-9000 Sailor / Cobham 6000 GMDSS / FleetBroadband Raytheon Anschütz Synapsis / Standard 22 Danelec Marine DM100 / DM200 / DM300 Consilium S-VDR / F2 / Salwico FDAS MacGregor VDR G4 / Baldwin

Technical Specifications & Operational Coverage

Inspection Standard SOLAS Chapter III Regulation 20.8, IMO Resolution A.761(18)
Supported Brands VIKING Life-Saving Equipment, Survitec (DSB / RFD), Lalizas, Fujikura, Shanghai Youlong
Tests Conducted Working Pressure (WP) Test, Necessary Additional Pressure (NAP) Test, Floor Seam Test, Gas Inflation Test
Spares Supplied Hammar H20 Hydrostatic Release Units, Emergency Rations, First Aid Kits, Thermal Protective Aids (TPA), Pyrotechnics

Standard 5-Step Inflatable Life Raft Statutory Servicing Protocol

Our Class-approved technicians execute this standardized procedural workflow to ensure first-time compliance with attending Class surveyors and Indian Port State Control (PSC) inspectors:

  1. Container Visual Inspection & Gas Cylinder Weight Check

    Inspect fiberglass container exterior, verify hydrostatic date of CO2/N2 gas inflation cylinders, and check net charge weight.

  2. Chamber Inflation & Working Pressure (WP) Hold Test

    Inflate buoyancy chambers with dry air; monitor pressure gauge over 6-hour period with ambient temperature correction.

  3. Necessary Additional Pressure (NAP) Test & Relief Valve Verification

    Subject buoyancy tubes to double working pressure test (NAP); verify correct automatic opening of pressure relief valves.

  4. Emergency Equipment Pack Audit & Pyrotechnic Expiry Renewal

    Inspect SOLAS emergency rations, drinking water sachets, radar reflector, and replace expired distress pyrotechnics.

  5. Container Vacuum Resealing & Class Certificate Delivery

    Vacuum-seal raft into container with new sealing gasket and hydrostatic release unit (HRU); deliver with Class certificate.

24/7 Port & Anchorage Attendance Across India

Seanav Marine provides rapid shore-based and offshore launch boat boarding across all 170+ Major and Minor Indian Ports, including:

Jawaharlal Nehru Port (INNSA) Berth attendance in 2 hours; Mumbai Floating Light (BFL) outer anchorage attendance via Belapur launch pier.
Deendayal Port Kandla (INIXY) Full cargo terminal & Kandla Roads outer anchorage coverage; fast spares transit from Gandhidham warehouse.
Adani Mundra Port (INMUN) Private port fast-track gate clearance; Mundra Roads anchorage rendezvous and SPM tanker support.
Cochin Port / ICTT (INCOK) Willingdon Island depot; OPL East-West international shipping route rendezvous launch service.
Chennai Port & Ennore (INMAA) Coromandel Coast gateway; 3-hour gate pass SLA; Chennai Roads outer anchorage attendance.
Visakhapatnam & Paradip East Coast bulk and container hub; 24/7 shore technician boarding and pilot launch dispatch.

Download SOLAS Life Raft & HRU Inspection Reference Sheet

Visual guide for proper rigging of weak links, painters, and Hammar H20 hydrostatic release units.