Oil Discharge Monitoring Equipment (ODME) Annual Calibration & 5-Year Survey India
Seanav Marine delivers 24/7 certified Oil Discharge Monitoring Equipment (ODME) annual calibration, 5-year overhaul surveys, and statutory MARPOL Annex I compliance certification across all Indian ports (JNPT, Mumbai, Kandla, Mundra, Cochin, Chennai, Visakhapatnam, Paradip). Our factory-trained marine instrumentation engineers attend at berth and outer anchorage with certified calibration kits for Rivertrace (Smart ODME), JOWA (JOWA ODME), VAF Instruments (Oilcon Mark 5 / Mark 6), and KSB Seil Seres systems. We verify oil content measuring cells, sample feed pumps, flow meters, differential pressure transmitters, and GPS speed interfaces, issuing on-board Class-traceable calibration certificates to ensure zero Port State Control (PSC) downtime.
Supported OEM Equipment & Multi-Make Coverage
Our marine electronics engineers are factory-trained with proprietary OEM diagnostic interfaces, software keys, and genuine spare parts for leading bridge manufacturers:
Technical Specifications & Operational Coverage
| Service Scope | Annual Calibration, 5-Year Survey Overhaul, Measuring Cell Cleaning, Sample Pump Overhaul, Flow Meter Verification |
|---|---|
| Supported OEMs | Rivertrace (Smart ODME), JOWA (JOWA ODME), VAF Instruments (Oilcon Mark 5 / Mark 6), KSB Seil Seres |
| Statutory Standards | MARPOL 73/78 Annex I Regulation 31, IMO Resolution MEPC.108(49) as amended by MEPC.240(65) |
| Class Societies | IRS, DNV, ABS, Lloyd's Register, ClassNK, Bureau Veritas, RINA |
| Port Attendance SLA | Within 2 hours at major berths; within 4 hours at outer anchorages across India |
| Spares In Stock | Optical measuring cells, sample diversion solenoid valves, wiper motors, flow sensors, pressure transmitters |
| Certification Issued | Official Calibration Certificate & Class Surveyor-endorsed ODME Test Record Sheet |
Standard 6-Step Marine ODME Calibration Protocol
Our Class-approved technicians execute this standardized procedural workflow to ensure first-time compliance with attending Class surveyors and Indian Port State Control (PSC) inspectors:
-
Sample Extraction Pump & Motor Inspection
Inspect degasser unit, overhaul sample conditioning pump, verify motor running current, and check flow switch safety cut-outs.
-
Optical Measuring Cell Cleanliness & Zero Baseline Setting
Dismantle optical sample tube, clean optical windows with approved solvent, inspect automatic cleaning wiper blade, and calibrate optical zero with fresh distilled water.
-
Span Calibration with Certified Secondary Calibration Tool
Introduce manufacturer secondary calibration standard to verify oil content reading linearity from 0 to 1,000 ppm within statutory +/-10 ppm tolerances.
-
Overboard Overfill & Auto-Stop Diverter Valve Trip Verification
Simulate high oil discharge rate exceeding 30 liters per nautical mile to verify automatic closure of overboard discharge valve and routing to slop tank within 20 seconds.
-
Speed Log (NMEA 0183) & GPS Position Data Interfacing
Check vessel speed inputs from Doppler Log ($VDVHW) and GPS latitude/longitude logging to verify exact discharge rate per nautical mile calculation.
-
Master Printout & Class Calibration Certificate Endorsement
Run statutory simulation test printout, verify internal data memory retention, endorse ODME Oil Record Book Part II, and issue official calibration certificate.
24/7 Port & Anchorage Attendance Across India
Seanav Marine provides rapid shore-based and offshore launch boat boarding across all 170+ Major and Minor Indian Ports, including:
Certified Equipment & Replacement Spares in Stock
Seanav Marine maintains bonded warehouse spare parts inventory across major Indian ports for immediate dispatch and installation during port calls:
Download Tanker ODME & Oil Record Book Part II Pre-Survey Checklist
Ensure your ODME sample pump, wiper seals, and overboard valve interlocks are fully compliant before vetting inspection.