Seanav Marine

Auxiliary Engine Safety Shutdowns & Emergency Generator Testing India

SOLAS II-1 Reg 42/43 Certified Overspeed Trip Verification Blackout Start Verification
Official Statutory Service Scope

Seanav Marine carries out certified annual safety shutdown calibration and emergency generator auto-start testing at all Indian ports. Our flying squads calibrate mechanical overspeed trips, electronic pickup sensors, low lube oil pressure switches, and high cooling water temp cutouts on Yanmar, Daihatsu, MAN, and Wärtsilä gensets.

Supported OEM Equipment & Multi-Make Coverage

Our marine electronics engineers are factory-trained with proprietary OEM diagnostic interfaces, software keys, and genuine spare parts for leading bridge manufacturers:

Furuno VR-3000 / VR-7000 / FAR-2xx8 / FMD-3x00 JRC JCY-1800 / JCY-1900 / JMR-9200 / JAN-9201 Sperry Marine VisionMaster FT / Navigat 100/200 Tokyo Keiki TG-8000 / BR-3200 / PR-9000 Sailor / Cobham 6000 GMDSS / FleetBroadband Raytheon Anschütz Synapsis / Standard 22 Danelec Marine DM100 / DM200 / DM300 Consilium S-VDR / F2 / Salwico FDAS MacGregor VDR G4 / Baldwin

Technical Specifications & Operational Coverage

Engines Supported Yanmar (EY / N series), Daihatsu (DK / DC series), MAN B&W (L23/30, L28/32), Wärtsilä (L20 / W32), Caterpillar
Safety Trips Tested Mechanical & Electronic Overspeed Trip, Low Lube Oil Pressure (0.8-1.2 bar), High HT Water Temp (95°C), Common Rail Leakage Alarms
Class Accreditations IRS, DNV, ABS, ClassNK, Bureau Veritas, Lloyd's Register

Standard 5-Step Generator Safety Shutdown Calibration SOP

Our Class-approved technicians execute this standardized procedural workflow to ensure first-time compliance with attending Class surveyors and Indian Port State Control (PSC) inspectors:

  1. Electronic & Mechanical Overspeed Trip Testing

    Verify mechanical flyweight trip latch and inject frequency signals into electronic pickup unit to verify engine trip at exactly 112-115% rated RPM.

  2. Low Lube Oil Pressure Switch Hydraulic Calibration

    Calibrate pressure trip transmitters using portable deadweight tester, verifying shutdown solenoid energizes before pressure drops below safe hydrodynamic bearing threshold.

  3. High Jacket Water Temperature Cutout Test

    Heat temperature sensors in calibrated dry-block bath; verify alarm sounds at 90°C and automatic engine shutdown executes at 95°C.

  4. Emergency Fuel Quick-Closing Valve Pneumatic Trip

    Test quick-closing fuel shutoff valves from remote fire control station, verifying instantaneous closure within 2 seconds.

  5. Class Surveyor Demonstration & Official Endorsement

    Witness all generator safety cutouts with attending Class Surveyor; issue comprehensive Calibration Test Report.

24/7 Port & Anchorage Attendance Across India

Seanav Marine provides rapid shore-based and offshore launch boat boarding across all 170+ Major and Minor Indian Ports, including:

Jawaharlal Nehru Port (INNSA) Berth attendance in 2 hours; Mumbai Floating Light (BFL) outer anchorage attendance via Belapur launch pier.
Deendayal Port Kandla (INIXY) Full cargo terminal & Kandla Roads outer anchorage coverage; fast spares transit from Gandhidham warehouse.
Adani Mundra Port (INMUN) Private port fast-track gate clearance; Mundra Roads anchorage rendezvous and SPM tanker support.
Cochin Port / ICTT (INCOK) Willingdon Island depot; OPL East-West international shipping route rendezvous launch service.
Chennai Port & Ennore (INMAA) Coromandel Coast gateway; 3-hour gate pass SLA; Chennai Roads outer anchorage attendance.
Visakhapatnam & Paradip East Coast bulk and container hub; 24/7 shore technician boarding and pilot launch dispatch.

Download Auxiliary Engine Safety Trips & Alarm Test Sheet

Standardized calibration protocol for auxiliary engines and emergency generator automated start sequences.